D.C.4 point starter

The formation of this starter has been shown in the figure. We have seen that DC motors can not be combined with direct supply because the motor is damaged. To avoid this, the starter is used. We use the DC stator And we will now know about the DC4 point starter
           


                   Its composition has been shown as shown in the figure. We can see that one end of the DC solution is given in overloaded relay, and given in the handle. It is arranged in accordance with the order of the motor of the motor through Resistance. .and the other end of the DC clearway is given directly to the other terminal of the motor, ie, the starter is attached to the motor series. The nvc coil is also found in the stator Holds the handle on the motor coming to the fullspeed
                     Now when the collapse of the current supply falls, the magnetism of the nvc coil will be lost and the handle will come back into a closed position with the help of spring and the handle will not turn on until the reloaded handle is re-rotated.
                      Now when the current motors overload the question of overload, more flow will pass through the overloaded relay, and in it the magnet produces the strip against it as a result and both the nvc coil's terminal short nvc coil magnetism is destroyed and the handle will be re-closed. And the motor will be closed
                          So this was the 4 point starter's procedure

Labels:

Tuesday, 12 September 2017

D.C 3 POINT STARTER

               
                 It can also be called a three point starter. Its structure is shown in Figure. To start the motor, the handle is moved from off position to the first contact position. The total obstacle is in the armature circuit, the field connection is connected directly to the supply through a volt coil. Comes in as soon as the speed of the motor increases in the same way as the archete back emf emits and decreases in the value of current Now the handle is moved to the second step. Again this type of function will be done eventually at the last step of the handle. This time the armature will connect directly to the supply and this time the handle does not come with a no-volt coil. The magnet will hold the handle in the walt coil, and the motor will not need to hold the handle to continue and the motor will rotate in full speed.
                  Mechanism of 3 points Starter is done so that if the magnetism of the nvc coil is exhausted for any reason, and the handle will be re-off position through the spring, then the supply will not be supplied directly to the motor, with the handle again All the process has to be done, the overloaded relay in the starter is also fitted. It also protects from overload. In the mechanism of which the motor is overloaded
                         There is a 3-point Starter equipped with such safety systems